Discover the elements of YourPDU

Fully according to your wishes, from custom-made to plug & play.

 

Cable / Cable Entry

23%

Your PDU comes equipped with the correct connector and a connection cable at the proper length. Moreover, the cable connection is provided at exactly the location you need it. The ultra-flexible cable is specially manufactured for Schleifenbauer and meets LSZH specification. Its oversized diameter results in a lower build-up of heat and lower energy consumption. In addition to a standard connection via a connector, there is also the option of using a terminal connection.

Specifications:

Cable

  • Length is adjustable
  • Choice of connector
  • Connector IEC320 C14 & C20 can be supplied with an optional lock
  • Low Smoke Zero Halogen (LSZH)
  • Oversized diameter
  • Optional terminal connection

Cable Connection

  • Choose the location of the cable entry:
    • Top
    • Base
    • Front
    • Rear

Connectors:

CEE 7_4 connector

01

IEC320 C14

02

Connector - IEC320 C20

03

Connector - IEC60309 1fase (CEE)

04

Connector - IEC60309 3fase (CEE)

05

6ft-england-uk-notebook-power-cord-polarized-with-fuse

06

Connector - GST 18_3

07

Connector - T13

08

Connector - T23

09

Options

  1. CEE 7/4 (Schuko)
    CEE 7/5 (UTE)
  2. IEC320 C14
  3. IEC320 C20
  1. IEC60309 1 phase (IP44/IP67)
  2. IEC60309 3 phase (IP44/IP67)
  3. BS 1363
  4. GST 3/18
  1. T13
  2. T23
  3. Cable connection
  4. Terminal connection

Connections:

10

11

 

Fuses / Surge Protection

23%

Nowadays, it is hard to imagine a data centre that isn’t equipped with the highest possible level of safety protection. It is even a legal requirement to use fuses in certain situations. Fuses can be used in YourPDU according to your requirements and infrastructure. This ensures continuity and reduces the chance of a power outage.

Specifications:

Fuses

  • Unrestricted choice of fuse type, including:
    • Miniature Circuit Breaker (MCB)
    • Thermal fuse
    • Glass cardridge fuse holder
    • PASCO cartridge holder

Surge protection

  • Protects PDU against surges
  • Hot swap
  • Can be replaced by a data centre engineer

 

 

 

 

Options

  1. Glass cardridge fuse holder
  2. Thermal fuse
  3. MCB
  4. Surge protection
 

Housing

23%

Your PDU’s housing is made entirely out of aluminium, due to its excellent thermal properties and low weight. You can determine the length and orientation (horizontal or vertical) yourself. Our aluminium housing can be supplied in various colours and is provided with custom engraving.

Specifications:

 

  • Material:
    1.5mm anodised aluminium
  • Dimensions:
    • Length: adjustable
    • Width: 65mm
    • Depth: 52.6mm
  • Adjustable orientation

 

  • Colours:
    • Black
    • Green
    • Orange
    • Blue
    • Red
    • Yellow
  • Custom engraving
CEE 7_4 connector

01

IEC320 C14

02

Connector - IEC320 C20

03

6ft-england-uk-notebook-power-cord-polarized-with-fuse

04

Connector - GST 18_3

05

Connector - T13

06

Options

  1. Black*
  2. Green*
  3. Orange*
  4. Blue*
  1. Red*
  2. Yellow*
  3. Custom engraving

* The colours shown are for illustration purposes. Actual colours may vary.

07

 

Outputs

23%

Your PDU can be fitted with various (types of) outputs. You can configure both the number and type of outputs yourself. For example, IEC C13, IEC C19 and CEE 7/3 (Schuko). You can also specify the order in which you want the outputs to be arranged. IEC C13 and IEC C19 connectors come with an optional lock.

Specifications:

Various types of outputs:

  • IEC320 C13
  • IEC320 C13 IEC-lock
  • IEC320 C19
  • IEC320 C19 IEC-lock
  • CEE 7/3 (Schuko)
  • CEE 7/5 (UTE)

 

  • IEC60309 1 phase (IP44/IP67)
  • IEC60309 3 phase (IP44/IP67)
  • BS 1363
  • GST 18/3
  • T13
  • T23
IEC320 C13

01

IEC320 C13 IEC-lock

02

IEC320 C19

03

IEC320 C19 IEC-lock

04

CEE 7/4 (Schuko)

05

CEE 7/5 (UTE)

06

IEC60309 1 fase (IP44/IP67)

07

IEC60309 3 fase (IP44/IP67)

08

BS 1363

09

GST 18/3

10

T13

11

T23

12

Options

  1. IEC320 C13
  2. IEC320 C13 IEC-lock
  3. IEC320 C19
  4. IEC320 C19 IEC-lock
  1. CEE 7/3 (Schuko)
  2. CEE 7/5 (UTE)
  3. IEC60309 1 phase (IP44/IP67)
  4. IEC60309 3 phase (IP44/IP67)
  1. BS 1363
  2. GST 18/3
  3. T13
  4. T23
 

Mounting

23%

Specialised expertise is required in order to correctly install a PDU in a server rack. Schleifenbauer has the in-house know-how and offers mounting options for any type of server cabinet, regardless of the type or manufacturer. This includes the use of mounting brackets or even “toolless” mounting. What is your ideal mounting solution? If a standard mounting solution is not available, we can provide you with a customised alternative!

Specifications:

 

  • Not dependent on server rack manufacturer
  • Not dependent on type of server rack
  • Toolless mounting option
  • Customised mounting option
Horizontaal 19 inch

01

IEC320 C14

02

Connector - IEC320 C20

03

6ft-england-uk-notebook-power-cord-polarized-with-fuse

04

Connector - GST 18_3

05

Options

  1. Horizontal 19 inches
  2. Toolless mount
  3. Table mount
  4. Recessed
  5. Profile clamps
 

Residual Current Monitoring

23%

The residual current monitoring meter developed by Schleifenbauer enables you to easily localise leakage flows at the circuit level. Residual current monitoring can be used in a number of European countries to meet statutory safety requirements.

Specificaties:

 

  • Class B measurement
    (measurement of AC en DC components)
  • Auto-test
  • Single-phase and three-phase application
CEE 7_4 connector

01

CEE 7_4 connector

02

  1. Schematic diagram of residual current monitoring.
  2. Residual Current Sensor
 

Measurement

23%

The measurement readings on your PDU provide insight into energy flows, enabling you to manage them more effectively. You can read measurements locally or remotely, or you can also choose a PDU that does not include measurement readings (basic).

Select your configuration:

 

a.  No measurement reading (basic)
b.  Local measurement reading (local)
•  Current in A

 

c.  Remote measurement reading (remote)
•  Current in A
•  Power in W en VA
•  Energy in kWh
•  Voltage in V Powerfactor

Local

01

Remote

02

Options

  1. Local
  2. Remote

Manage Your PDU Remotely

23%

Webinterface
Our web interface is intuitive. A clear overview of all the information and easy settings adjustment.

Your data is straightforward and insightful
Your PDU data is integrated into your environment using open standards. Communication via various protocols such as SNMP (v1, v2c and v3), Modbus and API. Our applications are developed in well-known DCIM platforms such as PerfIT, Schneider InfraStruxure Manager, Sunbird DCIM and iTRACS®.

Webinterface

01

DCIM-platform van PerfIT

02

Options

  1. Web interface
  2. DCIM-platform of PerfIT
 

display

23%

If you choose remote measurement, the LCD display with LED backlight will provide you with all of the most important information such as measurement status and configuration. The information can be displayed horizontally or vertically, depending on your configuration. If a threshold value you have set is exceeded, this will be indicated on the display with an alert signal.

Specifications:

 

  • LCD-backlight
  • Horizontal/vertical display
LCD Display

LCD display

 

Outputs (data)

23%

The intelligence of YourPDU does not need to be limited to taking overall measurements. You can also choose to measure or activate/deactivate the outputs individually. Combining these options is also possible.

Specifications:

 

  • Energy measurement
    • Total PDU
    • Groups
    • Individual outputs
  • Individual outputs can be switched remotely; bi-stable relays are used for this.
 

Sensors

23%

Your PDU can be fitted with optional external sensors. Schleifenbauer supplies a combined sensor for temperature/humidity. It is also possible to add additional sensors, such as a water leak sensor based on binary input for potential-free contact.

Specifications:

  • Temperature measurement
  • Humidity measurement
  • Dry switch contact
    (based on binary input for potential-free contact)
Temperatuur/luchtvochtigheid sensor

temperature/humidity sensor