Looking for a specific PDU?

You have searched for a customer specific product number.

Our website contains only sample PDUs that can be customized to your needs. Are you looking for a specific model of PDU? We would be happy to help you on your way. Click the button below to contact us. Would you like your question answered immediately? Then call us at +31 (0)73-5230256. Prefer to ask your question via chat? Click on the chat button below to chat with a product expert.

What does our item number mean?

Would you like to know how our article number is structured and what the combination of letters and numbers means?
We are happy to explain it to you through an example.

Schleifenbauer opbouw artikelnummer PDU

Product number [627A VMN33 66]

[627A]

The left part of the product number is randomly selected by our system.

[VMN33]

The middle part of the product number is called the SPIS code and it tells more about the performance of the PDU. The intelligence, phase and amperage. The 5 letters and numbers in the example part number VMN33 mean:

V: Vertical
M: Energy measurement total + per fuse
N: Passive outlets
3: 3 phase
3: 32A

[66]

The right part of the product number shows the number of fuses and measured branch groups.

In the overview below you will find all possible meanings of the SPIS code in our article numbers.

V = Vertical
H = Horizontal
D = Double-deep horizontal
W = Double-deep vertical

N = No measurement basic PDU
I = Total energy measurement
M = Energy measurement total + per fuse
P = Packet power with 3 channels
Q = Packet power with 8 channels
X = Definilink PDU
C = Definilink controller

N = Passive outlets
M = Metered outlets
S = Switched outlets
B = Switched and measured per outlet
P = Pass through inline meter

1 = 1 phase
3 = 3 phase

1 = 16A
3 = 32A

Glossary

VNN1101 vertical PDU, single phase 16 A, basic
VIN1101 vertical PDU, single phase 16 A, metered input
VIM1101 Vertical PDU, single phase 16 A, metered input, metered outputs
VIS1101 Vertical PDU, single phase 16 A, metered input, switched outlets
VIB1101 vertical PDU, single phase 16 A, metered input, switched outputs,metered outputs
VNN3101 vertical PDU, three phase 16 A, basic
VIN3101 vertical PDU, three phase 16 A, metered input
VIM3101 vertical PDU, three phase 16 A, metered input, metered outputs
VIS3101 vertical PDU, three phase 16 A, metered input, switched outlets
VIB3101 vertical PDU, three phase 16 A, metered input, switched outputs,metered outputs
VNN1321 Vertical PDU, single phase 32 A, basic
VIN1321 vertical PDU, single phase 32 A, metered input
VIM1321 Vertical PDU, single phase 32 A, metered input, metered outputs
VIS1321 Vertical PDU, single phase 32 A, metered input, switched outlets
VIB1321 Vertical PDU, single phase 32 A, metered input, switched outputs,metered outputs
VMN1322 Vertical PDU, single phase 32 A, metered groups (2x)
VMM1322 Vertical PDU, single phase 32 A, metered groups (2x), metered outlets
VMS1322 Vertical PDU, single phase 32 A, metered groups (2x), switched outlets
VMB1322 Vertical PDU, single phase 32 A, metered groups (2x), switched outlets,metered outlets
VNN3361 vertical PDU, three phase 32 A, basic
VIN3361 vertical PDU, three phase 32 A, metered input
VIM3361 vertical PDU, three phase 32 A, metered input, metered outputs
VIS3361 Vertical PDU, three phase 32 A, metered input, switched outlets
VIB3361 vertical PDU, three phase 32 A, metered input, switched outputs,metered outputs
VMN3366 vertical PDU, three phase 32 A, metered groups (6x)
VMS3366 vertical PDU, three phase 32 A, metered groups (6x), switched outlets
VMB3366 vertical PDU, three phase 32 A, metered groups (6x), switched outlets,metered outlets
VIP1101 vertical PDU, single phase 16 A, metered input, inline meter (1 x CEE 3G2.5)
VIP1301 Vertical PDU, single phase 32 A, metered input, inline meter (1 x CEE 3G6)
VIP3101 vertical PDU, three phase 16 A, metered input, inline meter (3 x CEE 5G2.5)
VIP3301 vertical PDU, three phase 32 A, metered input, inline meter (3 x CEE 5G6)
DIP1101 dual horizontal PDU, single phase 16 A, metered input, inline meter (1 x CEE 3G2.5)
DIP1301 dual horizontal PDU, single phase 32 A, metered input, inline meter (1 x CEE 3G6)
DIP3101 dual horizontal PDU, three phase 16 A, metered input, inline meter (3 x CEE 5G2.5)
DIP3301 dual horizontal PDU, three phase 32 A, metered input, inline meter (3 x CEE 5G6)
HNN1101 horizontal PDU, single phase 16 A, basic
HIN1101 horizontal PDU, single phase 16 A, metered input
DIM1101 dual horizontal PDU, single phase 16 A, metered input, metered outputs
DIS1101 dual horizontal PDU, single phase 16 A, metered input, switched outlets
DIB1101 dual horizontal PDU, single phase 16 A, metered input, switched outputs,metered outputs
HNN3101 horizontal PDU, three phase 16 A, basic
HIN3101 horizontal PDU, three phase 16 A, metered input
DIM3101 dual horizontal PDU, three phase 16 A, metered input, metered outputs
DIS3101 dual horizontal PDU, three phase 16 A, metered input, switched outlets
DIB3101 dual horizontal PDU, three phase 16 A, metered input, switched outputs,metered outputs
HNN1321 horizontal PDU, single phase 32 A, basic
HIN1321 horizontal PDU, single phase 32 A, metered input
DMN1322 dual horizontal PDU, single phase 32 A, metered input, metered outputs
DIM1321 dual horizontal PDU, single phase 32 A, metered input, metered outputs
DIS1321 dual horizontal PDU, single phase 32 A, metered input, switched outlets
DIB1321 dual horizontal PDU, single phase 32 A, metered input, switched outputs,metered outputs
HMN1322 horizontal PDU, single phase 32 A, metered groups (2x)
DMM1322 dual horizontal PDU, single phase 32 A, metered groups (2x), metered outputs
DMS1322 dual horizontal PDU, single phase 32 A, metered groups (2x), switched outlets
DMB1322
dual horizontal PDU, single phase 32 A, metered groups (2x), switched outlets,metered outlets
DNN3361 dual horizontal PDU, three phase 32 A, basic
DIN3361 dual horizontal PDU, three phase 32 A, metered input
DIM3361 dual horizontal PDU, three phase 32 A, metered input, metered outputs
DIS3361 dual horizontal PDU, three phase 32 A, metered input, switched outlets
DIB3361 dual horizontal PDU, three phase 32 A, metered input, switched outputs,metered outputs
DMS3366 dual horizontal PDU, three phase 32 A, metered groups (6x), switched outlets
DMB3366
dual horizontal PDU, three phase 32 A, metered groups (6x), switched outlets,metered outlets
WIB3361 dual vertical PDU, three phase 32 A, metered input, switched outputs,metered outputs

23%

Schleifenbauer Products BV

Het Sterrenbeeld 52 
5215 ML ‘s-Hertogenbosch
The Netherlands
t +31 (0)73 52 30256
f +31 (0)73 521 23 83

 
23%

Request customer support

The serial number is located at the PDU on the front side, and at the DPM meter on the side

The better you describe your question or problem, the more focused we can help you